California
- Details
6" Linestop on Natural Gas HDPE Pipe in Vandenberg Air Force Base, CA.
Office hours 7:30 – 5:00 Central time
Nationwide: 1-800-221-3332
Emergency Services Available .
Job Date: November 27, 2017
JOB LOCATION: Vandenberg Air Force Base, CA
PROJECT: 6" Linestop®
Job Specifics:
Item I – 6” - linestop® on Natural Gas HDPE pipeline
1 - Mobilization – Prep / Travel
1 - 6” Hot tap on Natural Gas 6" HDPE Pipeline
- Details
30” Linestop with a 20” By-pass on AC Sewage Pipe, 30” Linestop on RCP Sewer Outfall Pipeline and 20” Hottap for Bypass Connection
Office hours 7:30 – 5:00 Central time
Nationwide: 1-800-221-3332
Emergency Services Available .
Job Date: March 28, 2018
JOB LOCATION: San Elijo, CA.
PROJECT: 30" Linestop Sewer Outfall
Job Specifics: 1- 30” Linestop with a 20” By-pass on AC Sewage Pipe, 1-30” Linestop on RCP Sewer Outfall Pipeline and 1-20” Hottap for Bypass Connection
Our Proposal is based on:
Installation of TWO 30” Linestops. One on AC Pipe, One on RCP. One Linestop (ACP) to have a 20” Flanged outlet and Temporary 20” Valve for By-pass Outlet, The second Linestop does not require a By-pass Outlet. We will also install a 30” x 20” Tapping Saddle ‘Tee’ on RCP, just west of our Linestop for By-pass use, which will include the use of a Temporary 20” Valve.
Please Note: We will use a Linestop Flange on the 30” x 20” Tapping Saddle so that we can install a Completion Plug and Blind Flange when the By-pass is complete, Thus, no permanent Valve remains on the Tapping ‘Tee’ All information based on Drawing C-13 sheet 19 of 21
ltem l Linestop - 30” on A/C Sewer Outfall Pipeline – under 100 psi
2 – Mobilizations / Travels to site – Installation of Linestops / Removal of Linestops
1 – 30” x 24” Linestop fittings for A/C Pipe (ANSI 150) (on One Linestop) JCM 442 Epoxy Coated with 304 - SS/ Hardware 1 - Installation of ONE 20” Temporary Valve for By-pass use. 1 – Installation of Assemblies with air test.
1 – Hot Taps to allow for Linestop entry
1 – Insertion of 30” Linestops for up to 30 days, while others perform pipeline work.
1– Removal of Linestops, install completion plugs and Blind Flanges
1 – Blow-off assembly as required
20” Flanged Outlet for By- Pass
ltem Il Linestop - 30” on RCP Sewer Outfall Pipeline No By-pass- under 50 psi
2 – Mobilizations / Travels to site – Installation of Linestops / Removal of Linestops
1 – 30” x 24” Linestop fittings for RCP Pipe (ANSI 150) JCM 442 Epoxy Coated with 304 - SS/ Hardware
1 – Installation of Assemblies with air test.
1 – Hot Taps to allow for Linestop entry
1 – Insertion of 30” Linestops for up to 30 days, while others perform pipeline work.
1– Removal of Linestops, install completion plugs and Blind Flanges
1 – Blow-off assembly as required
Item III 30” x 20” Hottap on RCP Sewer Outfall Pipeline – under 50 psi
1 - Travels to site
1 - 30” x 20” Tapping Saddle for RCP Pipe (ANSI 150) under 50 psi - JCM 442 Epoxy Coated with 304 - SS/ Hardware (Includes Completion Plug and Blind Flange) Includes use of Temporary 20” Valve on Tee for By-pass Use.
Item IV RE: Monel or Hastelloy Nuts & Bolts on Buried Fittings
All Fittings that will remain permanent / buried will be supplied with Monel or Hastelloy Nuts & Bolts as opposed to Stainless Steel.
- Details
6” Linestop on 6” PVC Pipeline under 150psi for a Casino
Job Date: May 23, 2018
JOB LOCATION: Temecula, CA.
PROJECT: Pechanga Casino
Item I: 6” Linestop on 6” PVC Pipeline under 150psi - below ground
1 – Mobilization – Prep / Travel to site
1 – 6” Linestop fittings for 6” PVC Water Pipeline (with SS/NB)
1 – Installation of temporary valve with air test.
1 – Hot Taps to allow for Linestop entry
1 – Insertion of 6” Linestop – held for up to 6 hours while ‘Others’ perform Pipeline Modifications.
1 – Removal of Linestops, installation of completion plugs and blind flanges Installation of Blow-off assemblies as required for removal of Linestop.
Office hours 7:30 – 5:00 Central time
Nationwide: 1-800-221-3332
Emergency Services Available .
- Details
17- 4" Hottaps in Long Beach, CA.
Office hours 7:30 – 5:00 Central time
Nationwide: 1-800-221-3332
Emergency Services Available .
Job Date: November 16, 2017
JOB LOCATION: Los Alamitos, CA.
PROJECT: Alamitos (OCWD) Project
1 – Mobilization – Prep / Travel to site
Item I – 4” Hottap on 12” A/C Domestic Waterline under 150 psi. Below Ground
2 – 4” Hottap on 12” A/C Waterline – below ground under 150 psi
2 - 12” x 4” JCM 432 Stainless Steel Tapping Saddle w/ SS nuts & Bolts (or Equal)
2 - 4” Mueller A2362 RW Gate Valve (or equal) – (excludes valve can & riser)
2 - Installation of fittings w/ pressure test & Hottap.
Item II – 4” Hottap on 10” A/C Domestic Waterline under 150 psi. Below Ground
6 – 4” Hottap on 10” A/C Waterline – below ground under 150 psi
6 - 10” x 4” JCM 432 Stainless Steel Tapping Saddle w/ SS nuts & Bolts (or Equal)
6 - 4” Mueller A2362 RW Gate Valve (or equal) – (excludes valve can & riser)
6 - Installation of fittings w/ pressure test & Hottap.
Item III – 4” Hottap on 8” DIP Domestic Waterline under 150 psi. Below Ground
5 – 4” Hottap on 8” DIP Waterline – below ground under 150 psi
5 - 8” x 4” JCM 412 Epoxy Coated Tapping Saddle w/ SS nuts & Bolts (or Equal)
5 - 4” Mueller A2362 RW Gate Valve (or equal) – (excludes valve can & riser)
5 - Installation of fittings w/ pressure test & Hottap.
Item IV – 4” Hottap on 8” A/C Domestic Waterline under 150 psi. Below Ground
3 – 4” Hottap on 8” A/C Waterline – below ground under 150 psi
3 - 8” x 4” JCM 432 Stainless Steel Tapping Saddle w/ SS nuts & Bolts (or Equal)
3 - 4” Mueller A2362 RW Gate Valve (or equal) – (excludes valve can & riser)
3 - Installation of fittings w/ pressure test & Hottap.
Item V – 4” Hottap on 6” DIP Domestic Waterline under 150 psi. Below Ground
1 – 4” Hottap on 6” DIP Waterline – below ground under 150 psi
1 - 6” x 4” JCM 412 Epoxy Coated Tapping Saddle w/ SS nuts & Bolts (or Equal)
1 - 4” Mueller A2362 RW Gate Valve (or equal) – (excludes valve can & riser)
1 - Installation of fittings w/ pressure test & Hottap.
- Details
1.5" Linestop on Copper Pipe in Santa Monica, CA.
Job Date: June 11, 2018
JOB LOCATION: Santa Monica, CA.
PROJECT: 201 Ocean Ave
1 – Mobilization – Prep / Travel to Job Site
Item: I – 1.5” Linestop® on Copper Domestic Hot Waterline – under 100 psi
3 –1.5” Linestop fitting for Copper, Domestic Waterline under 100 psi
3 – Installation of fittings
3 - Pressure Test and Hottap pipe for Linestop installation
3 – 1.5” Linestop held for up to 2 hours each while you perform pipeline modifications
3 – Removal Linestop and installation of completion plugs with caps
Item: II 1” FreezePlug on Copper Domestic HWR Water Pipe under 100 degrees (F)
2 – 1” FreezePlugs on Copper Water Service lines under 100 PSI / under 100 degrees
2 - Hold FreezePlugs for up to 2 hours each.
Office hours 7:30 – 5:00 Central time
Nationwide: 1-800-221-3332
Emergency Services Available .