IFT Featured Ohio Job: Double 42" Linestops on 42" PCCP in Avon Lake
- Details
IFT Featured Ohio Job: Double 42" Linestops on 42" PCCP in Avon Lake - 5.0 out of
5
based on
5 reviews
Double 42" Linestops on 42" PCCP Water Pipeline in Avon Lake, Ohio
Job Status: Successful and Completed
Job Date: October 15, 2018
JOB LOCATION: Avon Lake, OH.
PROJECT: Double 42" Linestop on PCCP Water Main
IFT is pleased to submit the following quotation.
For Linestop® Services
Line Pressure: 100 or less
Line Contents: Water Main
Flow Rate: Less Than 2 Feet per second (FPS) Flow Rate
Pipe Material: PCCP L-301 (Pipe OD = 50.5 Cylinder OD = 47.25)
Pipe Specifications: 42” – Horizontal Linestops
Maximum Flow Rate allowed: Flow rates of 1 ft/sec for Single Linestop® or 2 ft/sec for Double Linestop® shall not be exceeded.
ltem l Linestop® 42” PCCP Water Main – 30” By Pass
1 – Set Up and Mobilization to site
2 – 42” Linestop Fittings for PCCP L-301 Water Pipeline (100 PSI or less)
(JCM 445 Primer Coated Bodies / Epoxy Coated Water Way – Alloy bolts)
Installation of saddles with test
2 – 36” Hot Taps to allow for linestop entry
2 – Insertion of 48” linestop for 3 Days or Less
2 – 30” Epoxy Coated Blind Flanges with (2) lifting eyes
2– Removal of Linestop, install Completion Plugs and Blind Flanges.
(30” ANSI 150# Flanged outlet off linestop equipment for your by pass)
Job Date: October 15, 2018
JOB LOCATION: Avon Lake, OH.
PROJECT: Double 42" Linestop on PCCP Water Main
IFT is pleased to submit the following quotation.
For Linestop® Services
Line Pressure: 100 or less
Line Contents: Water Main
Flow Rate: Less Than 2 Feet per second (FPS) Flow Rate
Pipe Material: PCCP L-301 (Pipe OD = 50.5 Cylinder OD = 47.25)
Pipe Specifications: 42” – Horizontal Linestops
Maximum Flow Rate allowed: Flow rates of 1 ft/sec for Single Linestop® or 2 ft/sec for Double Linestop® shall not be exceeded.
ltem l Linestop® 42” PCCP Water Main – 30” By Pass
1 – Set Up and Mobilization to site
2 – 42” Linestop Fittings for PCCP L-301 Water Pipeline (100 PSI or less)
(JCM 445 Primer Coated Bodies / Epoxy Coated Water Way – Alloy bolts)
Installation of saddles with test
2 – 36” Hot Taps to allow for linestop entry
2 – Insertion of 48” linestop for 3 Days or Less
2 – 30” Epoxy Coated Blind Flanges with (2) lifting eyes
2– Removal of Linestop, install Completion Plugs and Blind Flanges.
(30” ANSI 150# Flanged outlet off linestop equipment for your by pass)
OR Call
Office hours 7:30 – 5:00 Central time
Nationwide: 1-800-221-3332
Emergency Services Available .