Featured Work
- Details
Emergency 2.5" Linestops on Copper Pipe with 1.5" bypass Taps at a Casino
Job Date: June 28, 2018
JOB LOCATION: Highland, CA.
PROJECT: A Casino
1 – Mobilization – Prep / Travel to Job Site
Item 1: 2.5" Linestop® on Copper Domestic Hot Waterline- under 100 psi
2 - 2.5" Linestop fittings for Copper, Domestic Waterline under 100 psi
2- Installation of fittings (Stainless Steel Full Wrap Tapping Sleeve)
2- Pressure Test and Hottap pipe for Linestop installation
2- 2.5" Linestops held for up to 4 hours each while you perform pipeline modifications
2 - Removal Linestops and installation of completion plugs with caps
Item II - 1.5" Hottap on 2.5" Domestic Copper Hot waterline under 150psi
2- 2.5" x 1.5" Hottap fittings for Domestic Copper waterline
2 - Installation of fittings, (Stainless Steel Full Wrap Tapping Sleeve)
2- Pressure test and Hottap pipe 2 - 1.5" Full Port Ball Valves (Anvil or equal)
2 - 1.5" Hottap on 2.5" Copper
Office hours 7:30 – 5:00 Central time
Nationwide: 1-800-221-3332
Emergency Services Available .
- Details
2 – 4” FreezePlugs on 4” Carbon Steel waterline
Job Date: June 28, 2018
JOB LOCATION: Long Beach, CA.
PROJECT: Hotel Pipe Freeze Plugs
1 – Mobilization – Prep / Travel to Job Site
Item I –4” - FreezePlugs on Sch. 40 Carbon Steel Chilled Water Line – Under 150 psi
2 – 4” FreezePlugs on 4” Carbon Steel waterline, at or under 100 degree (F)
FreezePlugs held for up to 4 hours each freeze while you perform modifications to the pipeline
Office hours 7:30 – 5:00 Central time
Nationwide: 1-800-221-3332
Emergency Services Available .
- Details
Dual 42" Linestops with 36" By Pass in Baltimore, MA.
Job Date: March 13, 2018
JOB LOCATION: Baltimore, MD
PROJECT: Sewage Force Main
Line Pressure: 30 PSI working pressure or less Line
Contents: Sewage Force Main
Pipe Material: PCCP Pipe
Specifications:
1 - Pipe OD = 58.00” – Cylinder OD = 50.75”
1 - Pipe OD = 56.00” – Cylinder OD = 50.75”
ltem l Linestop 42” PCCP Sewage Force Main – with 36" By Pass
1 – Set Up and Mobilization to site
2 – 42” Linestop fittings for PCCP Sewage Pipeline (30 PSI or less) (JCM 445 Epoxy Coated Bodies / Epoxy Coated Water Way – Alloy bolts) Installation of saddles with test by our customer.
2 – Hot Taps to allow for linestop entry
2 – Insertion of 42” linestop for 7 Days or Less
2– Removal of Linestop, install Completion Plugs and Blind Flanges.
Office hours 7:30 – 5:00 Central time
Nationwide: 1-800-221-3332
Emergency Services Available .
- Details
Dual 4” Carbon Steel Pipe Linestops in Nashville, TN.
Job Date: July 16, 2018
JOB LOCATION: Nashville, TN.
PROJECT: Vanderbilt
1 – Mobilization – Prep / Travel to Job Site
ltem l Linestop 4” Carbon Steel Pipe
2 – 4” Linestop fitting for Carbon Steel Chilled Water (100 PSI or Less) (Fitting provided by IFT and weld on by Contractor)
2 – Installation of temporary valve with air test.
2 – Hot Taps to allow for linestop entry
2 – Insertion of linestop for 1 day
2 – 3/4” Tap on contractor supplied and installed materials for blow down and equalizing pressure to remove linestop. (If Needed)
2– Removal of Linestop, install completion plug and cap
Office hours 7:30 – 5:00 Central time
Nationwide: 1-800-221-3332
Emergency Services Available .
- Details
4” pipeline freeze plug using liquid nitrogen for a hospital in Houston, TX.
Job Date: September 11, 2018
JOB LOCATION: Houston, TX.
PROJECT: 4" Pipe Freeze Plug
1 - Travel to site
Item I – ” FreezePlugs - No Glycol
1 –4 ” FreezePlug on steel pipe water 150 PSI, approx. 80 degrees or less Hold FreezePlugs for up to 4 hours.
Office hours 7:30 – 5:00 Central time
Nationwide: 1-800-221-3332
Emergency Services Available .