Featured Work
- Details
3-14" Linestops in Tampa, Florida
Job Date: March 22, 2018
JOB LOCATION: Tampa, FL
PROJECT: 3-14" Linestops
1 – Travel job site – Shipping of Machinery and return
Item I – 14” Linestop® on Chilled Water
3 – 14” Linestop® weld fittings for carbon steel under 100PSI Welding provided by others.
3 – 14” Mechanical Linestops held for up to 4 days while you perform pipeline modifications
3 – Removal linestops and installation of completion plugs with Blind Flanges
Item II – 14” Hot tap on Chilled Water
1 – 14” Tapping service through your provided weld fitting and gate valve.
Office hours 7:30 – 5:00 Central time
Nationwide: 1-800-221-3332
Emergency Services Available .
- Details
4- 4” Linestops on Carbon Steel Chilled Water Pipe in Tampa, Florida
Job Date: April 20, 2018
JOB LOCATION: Tampa, FL
PROJECT: 4- 4” Carbon Steel Chilled Water Pipe
1 – Travel to site
ltem l Linestop 4” Carbon Steel Chilled Water Pipe
4 – 4” Linestop Weld Fittings for Carbon Steel Hot and Chilled Water (Fitting provided by IFT and weld on by Contractor)
4 – Installation of temporary valve with air test.
4 – Hot Taps to allow for linestop entry
4 – Insertion of 4” linestops for 1 Day
4– Removal of Linestop, install Completion Plugs and Caps.
Office hours 7:30 – 5:00 Central time
Nationwide: 1-800-221-3332
Emergency Services Available .
- Details
24" Hottap for a 36" Linestop in Phoenix, Arizona
Job Date: May 16, 2018
JOB LOCATION: Phoenix, AZ
PROJECT: 36” Linestop
ltem l Linestop 36” Hobas FRP Watermain – No By Pass
1 – Loaner Knife Gates & Hot Taps to allow for linestop entry
1 – Insertion of 36” linestop (100 PSI or less) Left in line for (7) days (By others)
1 - 36” Linestop fittings, with installation and pressure test (By others)
1 - 24” Blind Flanges and Bolt-sets (By others)
1 - 2” Saddles with 2” Corp. stops, installations and taps
2– Removals of Linestops, install completion plugs and Install Blind Flanges
Office hours 7:30 – 5:00 Central time
Nationwide: 1-800-221-3332
Emergency Services Available .
- Details
17- 4" Hottaps in Long Beach, CA.
Office hours 7:30 – 5:00 Central time
Nationwide: 1-800-221-3332
Emergency Services Available .
Job Date: November 16, 2017
JOB LOCATION: Los Alamitos, CA.
PROJECT: Alamitos (OCWD) Project
1 – Mobilization – Prep / Travel to site
Item I – 4” Hottap on 12” A/C Domestic Waterline under 150 psi. Below Ground
2 – 4” Hottap on 12” A/C Waterline – below ground under 150 psi
2 - 12” x 4” JCM 432 Stainless Steel Tapping Saddle w/ SS nuts & Bolts (or Equal)
2 - 4” Mueller A2362 RW Gate Valve (or equal) – (excludes valve can & riser)
2 - Installation of fittings w/ pressure test & Hottap.
Item II – 4” Hottap on 10” A/C Domestic Waterline under 150 psi. Below Ground
6 – 4” Hottap on 10” A/C Waterline – below ground under 150 psi
6 - 10” x 4” JCM 432 Stainless Steel Tapping Saddle w/ SS nuts & Bolts (or Equal)
6 - 4” Mueller A2362 RW Gate Valve (or equal) – (excludes valve can & riser)
6 - Installation of fittings w/ pressure test & Hottap.
Item III – 4” Hottap on 8” DIP Domestic Waterline under 150 psi. Below Ground
5 – 4” Hottap on 8” DIP Waterline – below ground under 150 psi
5 - 8” x 4” JCM 412 Epoxy Coated Tapping Saddle w/ SS nuts & Bolts (or Equal)
5 - 4” Mueller A2362 RW Gate Valve (or equal) – (excludes valve can & riser)
5 - Installation of fittings w/ pressure test & Hottap.
Item IV – 4” Hottap on 8” A/C Domestic Waterline under 150 psi. Below Ground
3 – 4” Hottap on 8” A/C Waterline – below ground under 150 psi
3 - 8” x 4” JCM 432 Stainless Steel Tapping Saddle w/ SS nuts & Bolts (or Equal)
3 - 4” Mueller A2362 RW Gate Valve (or equal) – (excludes valve can & riser)
3 - Installation of fittings w/ pressure test & Hottap.
Item V – 4” Hottap on 6” DIP Domestic Waterline under 150 psi. Below Ground
1 – 4” Hottap on 6” DIP Waterline – below ground under 150 psi
1 - 6” x 4” JCM 412 Epoxy Coated Tapping Saddle w/ SS nuts & Bolts (or Equal)
1 - 4” Mueller A2362 RW Gate Valve (or equal) – (excludes valve can & riser)
1 - Installation of fittings w/ pressure test & Hottap.
- Details
6” Linestop on 6” PVC Pipeline under 150psi for a Casino
Job Date: May 23, 2018
JOB LOCATION: Temecula, CA.
PROJECT: Pechanga Casino
Item I: 6” Linestop on 6” PVC Pipeline under 150psi - below ground
1 – Mobilization – Prep / Travel to site
1 – 6” Linestop fittings for 6” PVC Water Pipeline (with SS/NB)
1 – Installation of temporary valve with air test.
1 – Hot Taps to allow for Linestop entry
1 – Insertion of 6” Linestop – held for up to 6 hours while ‘Others’ perform Pipeline Modifications.
1 – Removal of Linestops, installation of completion plugs and blind flanges Installation of Blow-off assemblies as required for removal of Linestop.
Office hours 7:30 – 5:00 Central time
Nationwide: 1-800-221-3332
Emergency Services Available .