1-800-221-3332
Contact us Today!

 Anchorage, AK • Delaware, DE • Oklahoma City, OK • Nashville, TN • New Orleans, LA • Houston, TX

30” Linestop with a 20” By-pass on AC Sewage Pipe, 30” Linestop on RCP Sewer Outfall Pipeline and 1-20” Hottap for Bypass Connection

30” Linestop 20” By-pass on AC Sewage Pipe, 30” Line stop on RCP Sewer Outfall Pipe & 20” Tap for Bypass - 5.0 out of 5 based on 18 reviews

User Rating: 5 / 5

Star ActiveStar ActiveStar ActiveStar ActiveStar Active

30” Linestop with a 20” By-pass on AC Sewage Pipe, 30” Linestop on RCP Sewer Outfall Pipeline and 20” Hottap for Bypass Connection

1- 30” Linestop with a 20” By-pass on AC Sewage Pipe, 1-30” Linestop on RCP Sewer Outfall Pipeline and 1-20” Hottap for Bypass Connection
OR Call

Office hours 7:30 – 5:00 Central time

Nationwide: 1-800-221-3332

Emergency Services Available .

 

 

Job Status: Successful and Completed
Job Date: March 28, 2018
JOB LOCATION:  San Elijo, CA.
PROJECT: 30" Linestop Sewer Outfall

Job Specifics: 1- 30” Linestop with a 20” By-pass on AC Sewage Pipe, 1-30” Linestop on RCP Sewer Outfall Pipeline and 1-20” Hottap for Bypass Connection

Our Proposal is based on:
Installation of TWO 30” Linestops. One on AC Pipe, One on RCP. One Linestop (ACP) to have a 20” Flanged outlet and Temporary 20” Valve for By-pass Outlet, The second Linestop does not require a By-pass Outlet. We will also install a 30” x 20” Tapping Saddle ‘Tee’ on RCP, just west of our Linestop for By-pass use, which will include the use of a Temporary 20” Valve.

Please Note: We will use a Linestop Flange on the 30” x 20” Tapping Saddle so that we can install a Completion Plug and Blind Flange when the By-pass is complete, Thus, no permanent Valve remains on the Tapping ‘Tee’ All information based on Drawing C-13 sheet 19 of 21

ltem l Linestop - 30” on A/C Sewer Outfall Pipeline – under 100 psi
2 – Mobilizations / Travels to site – Installation of Linestops / Removal of Linestops
1 – 30” x 24” Linestop fittings for A/C Pipe (ANSI 150) (on One Linestop) JCM 442 Epoxy Coated with 304 - SS/ Hardware 1 - Installation of ONE 20” Temporary Valve for By-pass use. 1 – Installation of Assemblies with air test.
1 – Hot Taps to allow for Linestop entry
1 – Insertion of 30” Linestops for up to 30 days, while others perform pipeline work.
1– Removal of Linestops, install completion plugs and Blind Flanges
1 – Blow-off assembly as required 
20” Flanged Outlet for By- Pass

ltem Il Linestop - 30” on RCP Sewer Outfall Pipeline No By-pass- under 50 psi
2 – Mobilizations / Travels to site – Installation of Linestops / Removal of Linestops
1 – 30” x 24” Linestop fittings for RCP Pipe (ANSI 150) JCM 442 Epoxy Coated with 304 - SS/ Hardware
1 – Installation of Assemblies with air test.
1 – Hot Taps to allow for Linestop entry
1 – Insertion of 30” Linestops for up to 30 days, while others perform pipeline work.
1– Removal of Linestops, install completion plugs and Blind Flanges
1 – Blow-off assembly as required 

Item III 30” x 20” Hottap on RCP Sewer Outfall Pipeline – under 50 psi
1 - Travels to site
1 - 30” x 20” Tapping Saddle for RCP Pipe (ANSI 150) under 50 psi - JCM 442 Epoxy Coated with 304 - SS/ Hardware (Includes Completion Plug and Blind Flange) Includes use of Temporary 20” Valve on Tee for By-pass Use.

Item IV RE: Monel or Hastelloy Nuts & Bolts on Buried Fittings
All Fittings that will remain permanent / buried will be supplied with Monel or Hastelloy Nuts & Bolts as opposed to Stainless Steel.

Go to top